Skip to Content
Browse documentation

Edit LiteSpeed Website Settings in UAPP

Understand all 13 OpenLiteSpeed website switches, application-profile changes, configuration inheritance and reset behavior in UAPP.

Open LiteSpeed → LiteSpeed Websites, select the advanced-settings action and acknowledge its warning. Verify the website, current application and configuration badge.

Core features

Each switch submits on or off.

FieldSettingPurpose
User Directory AccessuserdirUser-directory access for the website; see the limitation below.
LSCachelscacheConfigured LiteSpeed caching.
Google PageSpeedpagespeedPageSpeed optimization when installed.
Directory ListingdirlistDirectory contents when no index file exists.
Hotlink ProtectionhotlinkConfigured rules against unauthorized static-file linking.
HTTP Strict Transport SecurityhstsBrowser HTTPS policy.

Use LSCache with application-appropriate exclusions for private content. PageSpeed requires server support; the switch does not install it. Enable HSTS only with reliable HTTPS and an understanding of the provider's policy.

Security headers

FieldSettingPurpose
Content Security PolicycspRestrict permitted content sources through the configured policy.
XSS ProtectionxxpSend the legacy X-XSS-Protection header.
Clickjacking ProtectionxfoControl framing through X-Frame-Options.
Content-Type ProtectionxctoPrevent MIME sniffing through the configured response header.
Referrer PolicyrpsControl browser referrer information.
Expect-CTectConfigured certificate-transparency response header.
Feature PolicyfpgConfigured browser-feature access policy.

These are switches for generated policies, not free-text header editors. Review actual policies with the provider. Test scripts, external assets, embeds and integrations; an enabled header is not a complete security assessment.

User Directory Access limitation

User Directory Access also reads its initial state from a separate top-level website value, while this editor's save helper records it inside the OpenLiteSpeed overrides. Do not assume this switch changes the separate website-access setting. Ask the provider to verify the effective configuration.

The list's quick switches, reset and separate application-profile action use their own handlers.

Save or discard

The editor highlights changed switches and counts unsaved changes.

  1. Review all visible settings.
  2. Select Save LiteSpeed Settings.
  3. Review the change summary and website in the confirmation.
  4. Confirm, then read validation or result messages.
  5. Refresh and test the website if the operation succeeds.

Saving submits all 13 settings as website overrides. Every setting is required by the server form. Discard Changes leaves without saving pending form changes.

Change application profile

Select Change Application, choose Default Application or a provider-offered profile, then confirm Change Application. This separate form changes the website's application profile and requests a virtual-host rebuild.

It does not install, migrate or upgrade application code. Save or discard other pending editor changes before switching, and record the previous profile.

Reset to defaults

Select Reset to Defaults, verify the website and confirm the reset. This removes all recorded OpenLiteSpeed overrides, including quick-switch values. It does not reset the separate application profile or unrelated top-level website settings.

Record your overrides first. If a rebuild fails, refresh before retrying because stored settings may already have changed. Ask the provider to inspect the effective configuration and website availability.