HTTPD MPM Tuning
Select and tune Apache Prefork, Worker or Event in Eenos, with exact field constraints and reset values.
Open Web Servers → Apache HTTPD → HTTPD MPM Tuning.
The page displays the configured MPM and selector cards for Prefork, Worker and Event. Selecting a card displays its form; saving or resetting that form updates the configuration. Selecting a card alone does not apply it.
Before changing modes
Review the installed modules, PHP handling, workload and available resources. The configured badge reflects saved preferences, not independent verification of the running Apache module.
Saving can switch the module
A successful configuration-generation path updates the selected MPM module link as well as its tuning configuration. This page does not comprehensively check module compatibility or capacity relationships. Verify the resulting configuration before using Restart HTTPD.
Prefork fields
| Field | Requirement | Reset value |
|---|---|---|
| Start Servers | Integer at least 1. | 5 |
| Minimum Spare Servers | Integer at least 1. | 5 |
| Maximum Spare Servers | Integer at least 1. | 10 |
| Maximum Request Workers | Integer at least 1. | 250 |
| Connections per Child | Integer at least 0. | 0 |
Prefork uses server-process settings rather than thread fields.
Worker and Event fields
| Field | Requirement | Reset value for either mode |
|---|---|---|
| Start Servers | Integer at least 1. | 3 |
| Minimum Spare Threads | Integer at least 1. | 75 |
| Maximum Spare Threads | Integer at least 1. | 250 |
| Threads per Child | Integer at least 1. | 25 |
| Maximum Request Workers | Integer at least 1. | 400 |
| Connections per Child | Integer at least 0. | 0 |
Reset values describe the installed reset helper, not a recommended tuning profile. The forms enforce individual minima but do not validate all relationships among spare limits, threads, workers and available memory.
Save and apply
- Record the current mode and its values.
- Select the desired card.
- Complete every displayed field.
- Click Save Prefork Settings, Save Worker Settings or Save Event Settings.
- Review the result and validate the generated configuration and module compatibility.
- Click Restart HTTPD, confirm, and verify the running service and hosted sites.
Saving writes the chosen mode and its fields, regenerates the MPM configuration and, when generation succeeds, changes the configured module. The saved structure contains the selected mode's values; do not assume unsaved values for another card remain available.
The helper's success result primarily reflects preference saving; generation or activation problems require separate verification. No automatic restart follows a save.
Reset defaults
Use Reset Defaults within the intended mode and confirm. Resetting also selects that mode in the saved configuration and attempts generation/module selection. It is not just a local form reset. Review the values above, validate and restart when ready.
Demo sessions cannot save, reset or restart. On validation errors, correct the fields. On I/O or restart errors, inspect the generated configuration, module availability and service logs before retrying.